Zinco Separation and Slip sheet TGF 20, dimensions 8 x 25 m, 0.2 mm, black
Neutral, unplasticised / free of plasticizer film made of polyethylene (LDPE), can be used, for example, as a separating and sliding layer on roofs and underground garages.
UV-stabilized / protected against UV light, compatible with bitumen, compatible with polystyrene, made of LDPE, Weight approximately / approx. 190 g/sqm, supplied folded on a roll, 1 m wide, vapour barrier (sd >= 40 m), coefficient of sliding friction 0.30
| Order Nr.: | 1020 |
|---|---|
| Colour: | black |
| Length [m]: | 25,0 |
| Material: | LDPE |
| Width [m]: | 8,0 |
| Thickness [mm]: | 0,2 |
| Packaging unit: | Role |
| Weight [g/m²]: | 190,0 |
| WDD-equivalent air layer thickness [m]: | sd ≥ 40 |
| Sliding coefficient: | 0,29 |
| Compatible with bitumen: | Yes |
| Non-rotting: | Yes |
| UV-stabilized / protected against UV light: | Yes |
made of LDPE, Thickness approx. 0.2 mm, Weight approx. 190 g/m², black, UV-stabilized / protected against UV light, compatible with bitumen and polystyrene, vapour barrier (sd > 100 m), deliver and install with 10 cm joint overlap over the entire surface.
Product: Zinco Separation and Slip sheet TGF 20
Unit: m²
Order Nr.: 1020
These Installation Instructions describe the essential steps for using this product. Please also observe the relevant standards and guidelines, in particular the occupational health and safety regulations.
Installation should not be carried out if there is a risk of storms.
1
Installation:
Lay loose with approximately / approx. 10 cm overlapping.
After installation, the separating and sliding foil must be covered immediately (UV protection!) and secured against blowing away.
2
Cutting:
The film can be cut with a cutter knife (with a hard blade) or sturdy universal scissors. When cutting, make sure that the waterproofing of the roof is not damaged under any circumstances! If damage does occur, it must be reported and repaired immediately.
The foil must be cut out in a circle over roof outlets, approximately / approx. 1 cm larger than the roof outlet all round (cross cutting is not sufficient!).